When I run `naventity´ I don't see anything wrong (I also checked with an other switch, but the look the same). The switch have been in a stack before but being removed. I have tried to remove everything that have something to do with stacking from it. But it have a little to much power supplys!
[stack] +--5130-EI [chassis] (SERIALNUMBER) +--Level 1 Container #1 [container] | +--Board [module] (SERIALNUMBER) | +--Level 2 Virtual Container #0 [container] | +-- [module] | +--GigabitEthernet1/0/1 [port] | +--GigabitEthernet1/0/2 [port] | +--GigabitEthernet1/0/3 [port] | +--GigabitEthernet1/0/4 [port] | +--GigabitEthernet1/0/5 [port] | +--GigabitEthernet1/0/6 [port] | +--GigabitEthernet1/0/7 [port] | +--GigabitEthernet1/0/8 [port] | +--GigabitEthernet1/0/9 [port] | +--GigabitEthernet.... | +--Ten-GigabitEthernet1/0/49 [port] (▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒) | +--Ten-GigabitEthernet1/0/50 [port] | +--Ten-GigabitEthernet1/0/51 [port] | +--Ten-GigabitEthernet1/0/52 [port] +--Level 1 Container #2 [container] | +--PSU 1 [powerSupply] +--Level 1 Container #3 [container] | +--PSU 2 [powerSupply] +--Level 1 Container #4 [container] | +--PSU 3 [powerSupply] +--Level 1 Container #5 [container] | +--FAN 1 [fan] +--Level 1 Container #6 [container] | +--FAN 2 [fan] +--Level 1 Container #7 [container] +--Level 1 Container #8 [container] +--Level 1 Container #9 [container] +--Level 1 Container #10 [container] | +--SENSOR 1 [sensor] +--Level 1 Container #11 [container] | +--SENSOR 2 [sensor] +--Level 1 Container #12 [container] | +--SENSOR 3 [sensor] +--Level 1 Container #13 [container] | +--SENSOR 4 [sensor] +--Level 1 Container #14 [container] +--Level 1 Container #15 [container] +--Level 1 Container #16 [container] +--Level 1 Container #17 [container] +--Level 1 Container #18 [container]
[stack]
/Mattias
----- Ursprungligt meddelande ----- Från: "Morten Brekkevold" morten.brekkevold@uninett.no Till: "Mattias Söderholm" mattias.soderholm@malax.fi Kopia: "nav-users" nav-users@uninett.no Skickat: måndag, 7 mar 2016 11:14:46 Ämne: Re: Portadmin - Problem with changing Vlan
On Fri, 4 Mar 2016 09:49:43 +0200 Mattias Söderholm mattias.soderholm@malax.fi wrote:
For a couple of week ago we could change Vlan in portadmin and save with our HP 5130 switches. But now with Nav 4.4.2 it only show error when saving. It says: Error setting vlan: SNMP Error: inconsistentValue (The set value is illegal or unsupported in some way).
What can be the problem?
There have been some recent bugfixes to the Portadmin tool, specifically regarding HP switches. I'll have John-Magne look into it.
There is error when we try to check connectivity for snmp for one of the switches via SeedDB also. That's because there's something wrong with Chassis detected. It got two Chassis detected and one is down. I have tried to delete the switch and added it again, but the N/A chassis is appearing after a while again!
5130-EI (serial: XXXXXXX, software: 7.1.045 Release 3109P05) <---- Down N/A (serial: N/A, software: 7.1.045) <--- Don't know where this comes from
If you run the `naventity` command against the switch, what does that produce?